Price: US$ 13.90/kg
Copper Terminals 01-p

Innovative Bell Entry Design with Superior Conductivity

Copper Terminals

Pioneering the industry in India, we are the first company to introduce bell entry copper terminals that facilitate easy cable entry and ensure reliable electrical connections. Manufactured from high conductivity seamless copper tube conforming to BS 2874-C101 and ASTM B152-C11000 standards, these terminals feature innovative inspection windows for visual confirmation of full conductor insertion, setting new standards in electrical connection reliability and safety.

Key Specifications

Material:

BS 2874-C101 / ASTM B152-C11000

Size Range:

1.5mm² to 240mm²

Temperature:

Up to 350°C (Nickel Plated)

Innovation:

Bell Entry with Inspection Window

Technical Specifications

Material & Standards

High conductivity seamless copper tube manufactured to BS 2874-C101 and ASTM B152-C11000 international standards, ensuring superior electrical conductivity and mechanical strength for critical electrical applications.

Innovative Features

First in India to introduce bell entry design for easy cable insertion, featuring inspection windows that provide visual confirmation of full conductor insertion, ensuring reliable electrical connections and installation confidence.

Size Range & Flexibility

Available from 1.5mm² to 240mm² with different stud hole sizes as required, providing comprehensive coverage for various cable sizes and application requirements in electrical installations.

Temperature-Specific Finishes

Uniform electro-tin plating for operating temperatures up to 150°C. For higher temperature applications (150°C to 350°C), electrolytic nickel plating is available for enhanced thermal performance.

Complete Product Range

Heavy Duty Copper Lugs

Robust construction for high-current applications, featuring enhanced mechanical strength and superior electrical conductivity for industrial and power distribution systems.

Light Duty Copper Terminals

Optimized for standard electrical applications, providing reliable connections with cost-effective solutions for general electrical installations and control systems.

Multi-Hole Copper Lugs

Available in 2-hole and 4-hole configurations for specialized applications requiring multiple connection points, ideal for transformer and distribution panel connections.

Copper Ferrules

Available in standard and long configurations for wire end protection and connection enhancement, ensuring secure terminations in control and instrumentation applications.

Special Applications & Custom Solutions

Our comprehensive range includes specialized solutions for demanding applications. Four-hole lugs are specifically designed for transformer connections, providing multiple secure attachment points for high-current applications. Long palm copper terminal lugs offer extended contact surfaces for enhanced current distribution in power systems.

Key Benefits
  •  Industry-first bell entry design in India
  •  Inspection windows for installation confidence
  •  High conductivity seamless copper construction
  •  Temperature-specific finish options
  •  Comprehensive size range coverage
  •  International standards compliance

Technical FAQ – Copper Terminals

What material should a copper cable lug use?

Copper cable lugs are made from copper, with the grade, temper and surface finish specified for the connection. Tin plating is commonly used to protect the surface. Brass cable-gland material and entry-thread specifications do not describe a copper compression lug. Confirm the material and finish on the product drawing.

How is a cable lug sized?

Specify the copper conductor cross-section in mm² or AWG/kcmil, conductor stranding class, barrel dimensions and palm stud-hole size. A matching nominal conductor size alone does not establish compatibility with every cable construction. Confirm palm width, hole spacing and any inspection opening required.

Are these lugs suitable for aluminium conductors?

Use a connector specifically identified for aluminium or a compatible bimetallic transition when connecting aluminium. Do not assume that a copper lug is suitable for aluminium conductors or that plating alone establishes compatibility.

How should a compression lug be installed?

Use the lug manufacturer’s specified tooling, die, crimp sequence and conductor preparation. Tighten the palm connection to the documented torque for the assembly. Installation details depend on the selected lug and cable; a universal torque or crimp setting is not appropriate.

What determines the current and temperature rating?

The cable, termination design, contact resistance, enclosure conditions and installation determine the permitted operating conditions. Material conductivity or a plating temperature limit is not a current or temperature rating for the complete termination. Request model-specific ratings and test documentation where required.

What information is needed for a quotation?

Send the conductor specification, lug drawing or sample dimensions, palm-hole arrangement, copper grade, finish, quantity and destination. Identify any required standard, inspection report or approval so feasibility and documentation can be confirmed before ordering.